Circular electromagnetic chucks
Electromagnetic chuck introduction
MW5 series electromagnets for lifting scrap steel have normal temperature type, high temperature resistant type, high frequency type, high frequency high temperature resistant type, etc. It is suitable for lifting cast iron ingots, steel balls and all kinds of scrap steel.
It is suitable for handling ingots, steel balls and all kinds of scrap steel. Its excitation mode can be constant voltage mode, strong excitation mode and over-excitation mode.
Pictures of electromagnetic suction cups
The main models of MW5 series electromagnets for lifting scrap steel are:
Normal temperature type: MW5-70L/1, MW5-80L/1, MW5-90L/1, MW5-100L/1, MW5-110L/1, MW5-120L/1, MW5-130L/1, MW5-150L/1, MW5-165L/1, MW5-180L/1, MW5-210L/1, MW5-240L/1. 240L/1;
High temperature resistant type: MW5-70L2, MW5-80L2, MW5-90L/2, MW5-100L/2, MW5-110L/2, MW5-120L/2, MW5-130L/2, MW5-150L/2, MW5-165L/2, MW5-180L/2, MW5-210L/2, MW5-240L/2. MW5-240L/2;
High-frequency models are: MW5-100L/1-75, MW5-110L/1-75, MW5-120L/1-75, MW5-130L/1-75, MW5-150L/1-75, MW5-165L/1-75, MW5-180L/1-75, MW5-210L/1-75, MW5-240L/1-75 Type;
High-temperature high-frequency type: MW5-100L/2-75, MW5-110L/2-75, MW5-120L/2-75, MW5-130L/2-75, MW5-150L/2-75, MW5-165L/2-75, MW5-180L/2-75, MW5-210L/2-75, MW5-240L/2-75 and so on. MW5-210L/2-75, MW5-240L/2-75, MW5-240L/2-75, etc.
The manufacturer undertakes the design, manufacture, installation and maintenance of standard non-standard electromagnets (electromagnetic suction cups).
Electromagnetic suction cup description
- Product name:MW5 series electromagnet for lifting scrap steel
- Alias: electromagnetic suction cup lifting suction cup electromagnet
- Model:MW5
- Category:Electromagnetic spreader
- Product Origin:Henan Xinxiang
- Non-standard custom: undertake non-standard manufacturing
- Whether spot: custom production
- Production cycle: 7~10 days
- Scope of supply:National
- Delivery: Self-pick-up or consignment on behalf of the
- Installation or not: installation is another charge
- After-sales service: one year warranty
- Delivery area: Henan Xinxiang Changyuan
Parameters of electromagnetic suction cup
External Dimensions of Electromagnet for Lifting Scrap Steel
Electromagnetic suction cup control mode and voltage and current characteristic curve
(Normal temperature type) electromagnet technical parameters table
Normal temperature type (voltage: DC=220V, energisation duration TD=60%) | ||||||||||||||
Model No. | MW5-70L/1 | MW5-80L/1 | MW5-90L/1 | MW5-100L/1 | MW5-110L/1 | MW5-120L/1 | MW5-130L/1 | MW5-150L/1 | MW5-165L/1 | MW5-180L/1 | MW5-210L/1 | MW5-240L/1 | ||
Overall dimensions mm | A | 700 | 800 | 900 | 1000 | 1100 | 1200 | 1300 | 1500 | 1650 | 1800 | 2100 | 2400 | |
B | 800 | 800 | 1090 | 1090 | 1150 | 1150 | 1150 | 1250 | 1250 | 1520 | 1800 | 1800 | ||
C | 160 | 160 | 200 | 200 | 220 | 220 | 250 | 250 | 250 | 370 | 400 | 400 | ||
D | 90 | 90 | 120 | 150 | 150 | 150 | 150 | 200 | 200 | 230 | 250 | 250 | ||
E | 32 | 32 | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 55 | 60 | 60 | ||
own weight(kg) | 490 | 620 | 800 | 1000 | 1350 | 1800 | 2010 | 2830 | 3450 | 4230 | 7000 | 9000 | ||
power(kw) | 3.3 | 3.96 | 5.9 | 6.6 | 7.7 | 9.02 | 12 | 14.3 | 16.5 | 22.5 | 23.8 | 23.9 | ||
amps(A) | 15 | 18 | 26.6 | 30 | 35 | 41 | 54 | 65 | 75 | 102 | 129 | 154 | ||
Suction lifting capacity (kg) | ingot | 2500 | 3000 | 4500 | 5500 | 6500 | 7500 | 8500 | 11000 | 12500 | 14500 | 21000 | 28000 | |
Cast iron ingot | 380/150 | 480/200 | 600/300 | 800/450 | 1000/600 | 1200/800 | 1400/1000 | 1900/1200 | 2300/1400 | 2800/1500 | 3500/2000 | 4800/1100 | ||
swarf | 120/50 | 150/80 | 250/100 | 400/150 | 500/200 | 600/250 | 700/300 | 1100/400 | 1300/450 | 1600/600 | 2200/900 | 2900/1100 | ||
Matching equipment | Rectifier control equipment | Not containing transformer KDP-3 | Not containing transformer KDP-4 | STQL-25E | STQL-32E | STQL-38E | ||||||||
containing transformer STQL-7E | containing transformer STQL-10E | containing transformer STQL-15E | containing transformer STQL-20E | |||||||||||
Cable reels | JTA30-15-2 | JTA50-15-2 | JTA80-15-2 | JTA125-15-2 | JTA175-15-2 | |||||||||
cable connector | DL-102 | DL-202 | ||||||||||||
Note: The technical parameters of submersible electromagnetic suction cups are the same as those of normal temperature electromagnetic suction cups. |
(High Temperature Resistant ) Electromagnet Technical Parameters Table
High-temperature type (voltage: DC = 220V, energisation duration TD = 60%, the temperature of sucked material is 100~700℃) Main technical parameters | ||||||||||||||
Model No. | MW5-70L2 | MW5-80L2 | MW5-90L/2 | MW5-100L/2 | MW5-110L/2 | MW5-120L/2 | MW5-130L/2 | MW5-150L/2 | MW5-165L/2 | MW5-180L/2 | MW5-210L/2 | MW5-240L/2 | ||
Overall dimensions mm | A | 700 | 800 | 900 | 1000 | 1100 | 1200 | 1300 | 1500 | 1650 | 1800 | 2100 | 2400 | |
B | 800 | 800 | 1090 | 1090 | 1150 | 1150 | 1150 | 1250 | 1250 | 1520 | 1800 | 1800 | ||
C | 160 | 160 | 200 | 200 | 220 | 220 | 250 | 250 | 250 | 370 | 400 | 400 | ||
D | 90 | 90 | 120 | 150 | 150 | 150 | 150 | 200 | 200 | 230 | 250 | 250 | ||
E | 32 | 32 | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 55 | 60 | 60 | ||
own weight(kg) | 520 | 650 | 900 | 1200 | 1500 | 2150 | 2300 | 3200 | 3700 | 4530 | 7200 | 9500 | ||
power(kw) | 2.64 | 3.52 | 4.51 | 5 | 6.05 | 7.92 | 8.93 | 11.3 | 13.3 | 19.8 | 22.8 | 26 | ||
amps(A) | 12 | 16 | 20.5 | 22.7 | 27.5 | 36 | 40.6 | 51.4 | 60.6 | 90 | 104 | 118 | ||
Suction lifting capacity (kg) | ingot | 2500 | 3000 | 4500 | 5500 | 6500 | 7500 | 8500 | 11000 | 12500 | 14500 | 21000 | 28000 | |
Cast iron ingot | 380/150 | 480/200 | 600/300 | 800/450 | 1000/600 | 1200/800 | 1400/1000 | 1900/1200 | 2300/1400 | 2800/1500 | 3500/2000 | 4800/1100 | ||
swarf | 120/50 | 150/80 | 250/100 | 400/150 | 500/200 | 600/250 | 700/300 | 1100/400 | 1300/450 | 1600/600 | 2200/900 | 2900/1100 | ||
Matching equipment | Rectifier control equipment | Not containing transformer KDP-3 | Not containing transformer KDP-4 | STQL-25E | STQL-32E | STQL-38E | ||||||||
containing transformer STQL-7E | containing transformer STQL-10E | Not containing transformer STQL-15E | Not containing transformer STQL-20E | |||||||||||
Cable reels | JTA30-15-2 | JTA50-15-2 | JTA80-15-2 | JTA125-15-2 | JTA175-15-2 | |||||||||
cable connector | DL-102 | DL-202 |
Electromagnetic suction cup manufacturers
MW5 normal temperature type, high temperature type, high frequency type, high temperature high frequency type electromagnet (electromagnetic suction cup), and rectifier control equipment, blackout magnetism protection equipment (electrical box), suction cups with cable reel and other peripheral equipment, such as model specifications, technical parameters, product characteristics, structural drawings, factory prices, as well as the common problems and failures, the merits and demerits of the product, please contact customer service consulting.
FAQ
Electromagnetic suction cups are used in conjunction with various lifting machines. Can be widely used in steel mills, rolling mills, steel scrap treatment plants, large foundries, shipyards, heavy machinery manufacturing plants, steel warehouses, port terminals and stations and other industries. It is used for loading, unloading and handling of magnetic materials.
1、Adopting fully sealed structure, good moisture-proof performance;
2、Optimised design by computer, reasonable structure, large suction-to-weight ratio, low energy consumption;
3、The excitation coil is treated by special technology, which improves the electrical and mechanical performance of the coil, and the heat-resistant grade of the insulating material reaches C level, with long service life;
4、According to different conditions of the sucked materials, different structures and parameters are adopted, which can widely meet the needs of users;
5、High temperature type electromagnetic suction cup adopts unique heat insulation method, which enhances the adaptable range of electromagnetic suction cup’s resistance to people;
6, installation, operation and maintenance is simple.
MW5 series electromagnet for lifting scrap steel, MW61 series oval electromagnetic suction cups, MW12 series rectangular electromagnetic suction cups for lifting bundled bars, MW22 series electromagnet for lifting billets, round billets, rail girders, MW84 series electromagnet for lifting medium and thick plates, electromagnet for lifting coiled wire rods (disc rounds), MW16, MW96, MW26, MW36 series electromagnet for lifting steel strips. Electromagnet; Manual permanent magnetic suction cup, automatic permanent magnetic suction cup; Electromagnetic separator, MC03 (RCDB) series round electromagnetic separator, MC23 series rectangular electromagnetic separator, MC22 series self-unloading electromagnetic separator and so on.
1, the main basis for the selection of electromagnetic suction cup is the material to be sucked;
2、Suction and transportation of scrap steel involves the accumulation of loose degree of material, block degree, material degree, working frequency and temperature data;
3、Suction and transport of finished materials involves the external dimensions of the material, the degree of material, the number of materials, working frequency and temperature data;
4、When the temperature of suction and transport materials is lower than 100℃, use room temperature type suction cup. If the temperature exceeds 100℃, use high temperature resistant suction cups. When the temperature exceeds 600℃, please specify;
5、When the continuous rate of energisation exceeds 60%, use the high frequency type suction cup;
6、When sucking materials under water, use submersible suction cups (diving depth < 100m). Since the diving-type suction cups and room temperature type suction cups are similar, the user please specify when ordering;
7, equipment supporting electrical: single suction cup use, according to the power consumption (current) selection of rectifier control equipment and auxiliary equipment; more than one suction cup joint use, according to the joint use of the number of units of the power consumption (current) and the total selection;
8, according to be sucked by the ease of transporting materials, the actual situation of the selection of suitable electromagnetic suction cups, but also to consider the type of each batch of materials and chemical nature of the changes in seasonal humidity on the suction cups suction with or without influence.